FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource Requirements/FHIR Server from package hl7.ehrs.ehrsfmr21#current (31 ms)

Package hl7.ehrs.ehrsfmr21
Type Requirements
Id Id
FHIR Version R5
Source http://hl7.org/ehrs/https://build.fhir.org/ig/mvdzel/ehrsfm-fhir-r5/Requirements-EHRSFMR2.1-TI.1.6.html
Url http://hl7.org/ehrs/Requirements/EHRSFMR2.1-TI.1.6
Version 2.1.0
Status active
Date 2024-11-26T16:30:50+00:00
Name TI_1_6_Secure_Data_Exchange
Title TI.1.6 Secure Data Exchange (Function)
Experimental False
Realm uv
Authority hl7
Description Secure all modes of EHR data exchange.
Purpose Whenever an exchange of EHR information occurs, it requires appropriate security and privacy considerations, including data obfuscation as well as both destination and source authentication when necessary. For example, it may be necessary to encrypt data sent to remote or external destinations.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found



Narrative

Note: links and images are rebased to the (stated) source

Statement N:

Secure all modes of EHR data exchange.

Description I:

Whenever an exchange of EHR information occurs, it requires appropriate security and privacy considerations, including data obfuscation as well as both destination and source authentication when necessary. For example, it may be necessary to encrypt data sent to remote or external destinations.

Criteria N:
TI.1.6#01 SHALL

The system SHALL secure all modes of EHR data exchange.

TI.1.6#02 SHALL

The system SHALL conform to function [[TI.1.7]] (Secure Data Routing).

TI.1.6#03 SHOULD

The system SHOULD provide the ability to de-identify data.

TI.1.6#04 SHALL

The system SHALL encrypt and decrypt EHR data that is exchanged over a non-secure link.

TI.1.6#05 dependent conditional SHALL

IF encryption is used, THEN the system SHALL exchange data using recognized standards-based encryption mechanisms according to organizational policy, and/or jurisdictional law.

TI.1.6#06 conditional SHOULD

IF the EHR-S is the recipient of a secure data exchange, THEN the system SHOULD provide the ability to transmit an acknowledgment of the receipt of the data.

TI.1.6#07 SHALL

The system SHALL provide the ability to determine static or dynamic addresses for known and authorized sources and destinations.


Source

{
  "resourceType" : "Requirements",
  "id" : "EHRSFMR2.1-TI.1.6",
  "meta" : {
    "profile" : [
      "http://hl7.org/ehrs/StructureDefinition/FMFunction"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <span id=\"description\"><b>Statement <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b> <div><p>Secure all modes of EHR data exchange.</p>\n</div></span>\n\n \n <span id=\"purpose\"><b>Description <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Informative Content\" class=\"informative-flag\">I</a>:</b> <div><p>Whenever an exchange of EHR information occurs, it requires appropriate security and privacy considerations, including data obfuscation as well as both destination and source authentication when necessary. For example, it may be necessary to encrypt data sent to remote or external destinations.</p>\n</div></span>\n \n\n \n\n \n <span id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></span>\n \n <table id=\"statements\" class=\"grid dict\">\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>TI.1.6#01</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL secure all modes of EHR data exchange.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>TI.1.6#02</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL conform to function [[TI.1.7]] (Secure Data Routing).</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>TI.1.6#03</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHOULD provide the ability to de-identify data.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>TI.1.6#04</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL encrypt and decrypt EHR data that is exchanged over a non-secure link.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>TI.1.6#05</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n <i>dependent</i>\n \n \n <i>conditional</i>\n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF encryption is used, THEN the system SHALL exchange data using recognized standards-based encryption mechanisms according to organizational policy, and/or jurisdictional law.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>TI.1.6#06</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n <i>conditional</i>\n \n \n <span>SHOULD</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>IF the EHR-S is the recipient of a secure data exchange, THEN the system SHOULD provide the ability to transmit an acknowledgment of the receipt of the data.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n <tr>\n <td style=\"padding-left: 4px;\">\n \n <span>TI.1.6#07</span>\n \n </td>\n <td style=\"padding-left: 4px;\">\n \n \n \n <span>SHALL</span>\n \n </td>\n <td style=\"padding-left: 4px;\" class=\"requirement\">\n \n <span><div><p>The system SHALL provide the ability to determine static or dynamic addresses for known and authorized sources and destinations.</p>\n</div></span>\n \n \n </td>\n </tr>\n \n </table>\n</div>"
  },
  "url" : "http://hl7.org/ehrs/Requirements/EHRSFMR2.1-TI.1.6",
  "version" : "2.1.0",
  "name" : "TI_1_6_Secure_Data_Exchange",
  "title" : "TI.1.6 Secure Data Exchange (Function)",
  "status" : "active",
  "date" : "2024-11-26T16:30:50+00:00",
  "publisher" : "EHR WG",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/ehr"
        }
      ]
    }
  ],
  "description" : "Secure all modes of EHR data exchange.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001",
          "display" : "World"
        }
      ]
    }
  ],
  "purpose" : "Whenever an exchange of EHR information occurs, it requires appropriate security and privacy considerations, including data obfuscation as well as both destination and source authentication when necessary. For example, it may be necessary to encrypt data sent to remote or external destinations.",
  "statement" : [
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-TI.1.6-01",
      "label" : "TI.1.6#01",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL secure all modes of EHR data exchange.",
      "derivedFrom" : "EHR-S_FM_R1.1 IN.1.6#1"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-TI.1.6-02",
      "label" : "TI.1.6#02",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL conform to function [[TI.1.7]] (Secure Data Routing).",
      "derivedFrom" : "EHR-S_FM_R1.1 IN.1.6#2"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-TI.1.6-03",
      "label" : "TI.1.6#03",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : false,
      "requirement" : "The system SHOULD provide the ability to de-identify data.",
      "derivedFrom" : "EHR-S_FM_R1.1 IN.1.6#3"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-TI.1.6-04",
      "label" : "TI.1.6#04",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL encrypt and decrypt EHR data that is exchanged over a non-secure link.",
      "derivedFrom" : "EHR-S_FM_R1.1 IN.1.6#4"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : true
        }
      ],
      "key" : "EHRSFMR2.1-TI.1.6-05",
      "label" : "TI.1.6#05",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : true,
      "requirement" : "IF encryption is used, THEN the system SHALL exchange data using recognized standards-based encryption mechanisms according to organizational policy, and/or jurisdictional law.",
      "derivedFrom" : "EHR-S_FM_R1.1 IN.1.6#5"
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-TI.1.6-06",
      "label" : "TI.1.6#06",
      "conformance" : [
        "SHOULD"
      ],
      "conditionality" : true,
      "requirement" : "IF the EHR-S is the recipient of a secure data exchange, THEN the system SHOULD provide the ability to transmit an acknowledgment of the receipt of the data."
    },
    {
      "extension" : [
        {
          "url" : "http://hl7.org/ehrs/StructureDefinition/requirements-dependent",
          "valueBoolean" : false
        }
      ],
      "key" : "EHRSFMR2.1-TI.1.6-07",
      "label" : "TI.1.6#07",
      "conformance" : [
        "SHALL"
      ],
      "conditionality" : false,
      "requirement" : "The system SHALL provide the ability to determine static or dynamic addresses for known and authorized sources and destinations."
    }
  ]
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.